CRAC,As is known to all, large equipment power density of high calorific value, so the volume data exchange, such as computer room still needs through constant refrigeration air-conditioning compressor to meet the needs of communications equipment to the environment temperature, the refrigerant through the pump running, the ethylene glycol solution as the carrier of cold agent for indoor and outdoor heat exchanger, prevent air conditioning compressor work, because the computer room precision air conditioning evaporator left and right sides of the joint is more, the likely funnelled more also, precision air conditioning refrigerant leakage is often the case, the main reason is that air conditioner factory employees poor welding technology, in the absence of the copper pipe burn red (did not reach a temperature of 600 ℃ ~ 600 ℃), just put the electrode in joint, copper tube and solder was not able to fuse together, causing joint holder welding, MaZha, leakage is not smooth, look at this several air conditioning refrigerant leakage point below how to patching.
Room for the newly installed the air conditioner, close the end of the valve, outdoor atmosphere to eliminate indoor machine, indoor machine evaporator leakage ring accidentally use ears to hear, visible leaking air conditioner, evaporator solder joints is put into a neglected, invented the evaporator leakage, the best welding, it lest the evaporator heat plastic shell deformation, helpless to the user account, assembly method is:
1. Find the missing spots and mark them well.
2. If there is another refrigerant in the refrigeration system, the refrigerant should be put into the outdoor unit first.
3. Unscrew the indoor machine with two 8-inch or 10-inch wrenches and unpack the electric box on the right side of the indoor machine.
4. Remove the rear of the evaporator and remove the strong pipe and splint, remove the indoor evaporator and position the screw.
5. The left hand lifts the pipe slightly from the back side of the chamber to make the evaporator move forward.
Pull the evaporator out of 5cm with your right hand, twist the evaporator 90 degrees with your hands and pull it out of the pipe.
Watch your hands for control. Don't touch the fins.
After the evaporator is unloaded, place it in a flat, clean place and wipe the oil stains with dry cloth.
The leakage point is soldered by silver solder, and the introspection must not leak, and the evaporator will be loaded back into the plastic frame of the indoor machine according to the assembly's reverse order.
Negative pressure sampling and density determination of refrigerant
(1) most of the lithium bromide absorption machine room air conditioning unit positive pressure sampling (hot and cold water unit) with the solution of the pump pressure is higher, dilute solution under the condition of positive pressure sampling, positive pressure sampling instruments and connections needed.
Sampling libr absorption (2) computer room air conditioning refrigeration unit (hot and cold water unit) of internal pressure is lower than the atmospheric pressure, in the cold agent sample, due to the low cooling pump pressure, the outlet pressure is lower than the atmospheric pressure, under the condition of negative pressure sampling, with the help of vacuum pump in the vacuum, the cooling water extract, concentrated solution of pressure is lower than the atmospheric pressure, if you need sample, under the condition of negative pressure sampling is required as well.
Some lithium bromide absorption units (cold and hot water units) have low pressure and dilute solution.
Negative pressure needed for the sampling instrument and its connection, in the management and maintenance of the equipment operation, sampling by dry cooling water or less concentrated solution, such as using the jar is not convenient, can replace jar with sampler.
(3) density determination of the density of the lithium bromide solution, is to determine the concentration of the solution, the concentration, temperature and density is directly related to the three parameters, determine the density and temperature, can determine the concentration of solution, amount of lithium bromide solution into the barrel should be measured as soon as possible, after determination, thermometer and densimeter amount must be inserted into the barrel, reading at the same time.
(4) computer room air conditioning temperature and density is measured, for example, the measured temperature of 30 ℃, density of 1560 kg/m3 find 30 ℃ for vertical line, on the horizontal coordinate of the vertical coordinates to find 1560 kg/m3 as a horizontal line, intersection of two lines can quality of lithium bromide solution concentration of 52% (mass fraction) refrigerant several leak and patching method:
(1) the cooling system of the low-pressure bypass valve core refrigerant is used to make up the refrigerant (commonly known as "gaff"), and it is necessary to raise the injection from the low pressure side.
With a thimble with a thimble, open the low pressure gas valve rod, and the air conditioner of the refrigerant cylinder of the r22 refrigerant gas is connected to the air conditioner.
The result of the leakage of the valve core is that the top pin of the air tube is too long, and the side air valve thimble is not less than the return of the cartridge, so that the valve core is not less than the reset.
The solution is to insert the key of the public air conditioner into the gas valve core to give a force to the valve core, so that the valve core spring will pop up, thus eliminating the leakage of the valve core.
(2) the leakage of the leaking pipeline of the hollow refrigerant of the pipeline is more than that of the family.
Some decorated workers do not understand refrigerant in the refrigerating line;
Bend at will, because there is insulation cover outside the line, the bent is not easy to be invented.
After the hollow of the pipeline, the refrigerant was omitted, and the cooling system was switched on again, and the cooling system presented two stop-flow symptoms.
Example: a split air conditioner is not refrigerated with pressure gauge, pressure gauge shows negative pressure, the gas is added to 0.45mpa, and the compressor is enlarged and the chamber machine has no air.
Remove the outer casing of the chamber, touch the evaporator not cool, peel off the indoor pipe insulation cover, and invent the low-pressure liquid pipe concave.
Use the cutter to remove the concave closure, adopt the method of the outer casing butt joint, and then, after the silver solder is welded, repress, leak, remove, and fluorine, and start up with the remote control.
However, the air conditioner inherits the above symptoms and clarifies that there are two other intercepting points in the pipeline.
The external pipe was stripped of the insulation cover and the low-pressure gas pipe was dented.
After finishing the outdoor piping, start the machine with the remote control and refrigerate the air conditioner.
(3) there are more leakage from the three copper pipes on the four valves of the air conditioner of the four-way reversing valve, and if there is oil trace at the Angle of the invention, the leakage point is clarified.
Band-aid approach is: first the Angle with a towel to clean oil stains, remember and washing spirit leak detection, the funnelled make logo with steel needle, and then release the refrigerant, the four-way reversing valve wound with a wet towel to cool.
When welding, be sure to control the flame skill according to its own control, aiming at the leakage point, and when the Angle reaches the welding temperature, the agile spot silver welding rod welding.
The maneuver should be quick, for the welding win, the test pressure.
The beginners are faced with the failure of the interangle of the four-way reversing valve. It is better to use the adhesive method to fill the leakage.
The core of nylon valve is close to the leakage point, and there is some difficulty in the welding. Improper operation will bake the core.
Once the four-way valve slider is in the air, the air conditioner is cold and hot, and it is a small failure of the original micro leak and becomes a non-changing four-way valve.
This gives users time and financial losses.
The four - way valve Angle gluing method is the same as the glue method of the compressor, after the test pressure leak detection, the pumping air, the air conditioner to the valve Angle leakage failure can be eliminated, the recovery of refrigeration.
(4) tightening machine terminal refrigerant leakage tightening machine terminal refrigerant leakage, accounted for over 2% of the leaking problem, over-current overheat protector cover, if there is oil stains, see tightening machine around the terminal has funnelled to clarify.
The solution is to unplug the air conditioner and write the note "someone fix the air conditioner on the roof, and the plug power" is attached to the socket.
To avoid the external retrencher at the top of the staff;
The indoor staff mistook the power to form a personal shock.
Then the pressure of the system is tested by adding the F22 table to the low pressure gas and the bypass valve.
If the pressure in the system is zero at this time, can be the first to system into 0.3 MPa pressure refrigerant gas, there is no pressure in the lest system, when leak detection by washing spirit, funnelled into tight oil washing spirit through the process, form a tightening machine shaft confound.
Pressure meter test system is under pressure, can be used to wash out the foam to reflect the leakage point of the post to do a sign.
Use dry cloth to adhere to the alcohol to wipe off the oil stains around the terminal posts, and use sandpaper to polish the new material around the terminal, and then use the hacksaw blade to mark the new baller, and to facilitate adhesion.
When the system pressure reaches negative 0.1mpa, the system will be used to make the system with a 1:1 ratio of C31 double pipe glue and apply it to the terminal.
For refrigeration system under vacuum condition, that C31 microcomputer infiltration seep into funnelled glue, funnelled glue also need 100 w light bulb in the adhesive after bake for 30 minutes, make glue into seep into funnelled more easily.
Be careful not to get too close to the C31 glue. It is appropriate to use the C31 glue 20cm. Otherwise, the gel will be baked and flow to the tightening machine. It will cause the leakage to be low.
After two hours of glue, the clamping machine can suppress and leak.
At the end of the time, fluoridation test, the cooling.
(5) the capillary shock outdoor ground leak air conditioner refrigeration, the refrigerant leakage reason reason, otherwise can happen when tightening machine work, make the two pipe friction occurs resonance, grinding wall leakage, the refrigerant.
Example: a hisense kfr-33g split air conditioner does not refrigerate, reflecting on the invention of capillary mill leakage.
The solution: the 6mm copper tube saw, wrapped in the capillary leak, and then silver soldered.
Also can be changed to the inner diameter of the capillary tube with the specification.
No flammable and explosive material shall be found in 1.5m before the replacement of welding.
The front of the capillaries must be covered with iron plates.
Welding flame don't too big, it is advisable to use neutral flame of fire, the temperature reaches 600 ℃, agile put the silver electrode weld crater.
Solder and copper tube melt together, the welding gun is agile apart, or it will burn the capillary.
This type of skill should be gradually understood by the staff while welding, and gradually control the welding skills.
(6) tightening machine outside u-shaped tube refrigerant leakage outdoor tightening machine U exhaust pipe leakage is wide, the main reason is because the brass tube wall thin, poor material, a u-shaped bend after bending, presents the small crack, tightening machine in the work of volatility to crack.
This kind of leakage problem mostly can leak the gas, wait for the indoor machine without cool breeze blow out, classics introspection is invented.
The test method is: wipe the oil trace with a soft cloth on the net, and weld the copper tube crack leak with silver solder.
Before welding, find a copper tube that is larger than the outer diameter of the exhaust pipe, and use a hacksaw saw to open and wrap in the crack, so as to avoid the leakage from this place.
Culture when remove the u-shaped tube of avoid by all means, it will make the tightening machine out of the low temperature low pressure refrigerant gas indirectly into the condenser, the condenser cooling down, refrigeration to low, at the same time, a volatile when tightening machine work.
After u-tube welding, add R22 gas from the end of the low pressure gas.
Test pressure leak detection, if there is no air bubble from the weld, explain the leakage of u-shaped pipe.