APC data machine room is a high quality, commercial machine room which provides server hosting and leasing for many customers.
However, if the design, construction and operation of IDC machine room do not meet the requirements of the relevant specifications, it is liable to produce hazardous materials, and the corrosion of electronic equipment may even threaten the normal operation of the equipment.
Therefore, both enterprises and government departments should attach great importance to the key technologies of APC building and control these key technologies to solve the problems related to the APC machine room.
1. Principles of construction of APC data machine room
APC room provides us with abundant, reliable, professional services and network resources, is an important business service center, and APC technology as an important technology of the modern information era, in providing professional network services and network resources plays an important role, so the construction of safe, reliable, economic and practical energy-saving APC data room is very necessary and important.
Therefore, the construction of APC data machine room must follow certain principles.
In the first place, the construction of APC should follow the principles of recent construction and long-term development planning to ensure the development of IDC business in the future.
Secondly, the APC construction shall conform to the relevant standards and norms of the project in accordance with the relevant standards and regulations of the present state and industry.
Ii. Key technical points of APC data machine room construction
(1) basic requirements of APC data machine room
Growing in recent years, the processing capacity of the server and the capacity increasing storage devices, and performance is more and more superior network equipment, all need to consume more electricity and use electricity costs increase sharply.
Usually have a lot of all kinds of APC room need to provide the adaptation of telecommunications equipment, and all the telecom equipment stability of the temperature and humidity environment, such as operating temperature range: APC room 20 ℃ to 25 ℃, relative humidity: 40% ~ 55%, depending on the equipment function and the different environmental requirements of computer room, IDC data room is mainly composed of mainframe, support area and supporting area, etc.
Among them, the computer room is the core of the IDC data room, its main function is to analyze the information processing, storage, use and transport, in the installation of equipment, in strict accordance with the standards, to ensure the installation quality.
Is common in general the IDC machine room, this kind of phenomenon, the main heat is run from the IT equipment, the sensible heat about which accounts for about 95% of the total quantity of heat, room a comparatively small amount of moisture, humidity is mainly by the staff and the infiltration of the outdoor air.
(2) IDC data machine room energy-saving technology
In the current situation of increasing energy consumption and the expansion of IT equipment, energy saving and consumption reduction work is under great pressure.
APC power consumption is mainly used in IT equipment and air-conditioning system.
Among them, refrigeration system accounts for about 48% of the total energy consumption of APC, so the energy saving of refrigeration system is very important, and there are two main types of energy-saving measures.
The first is to shorten the length of air conditioning use, including lowering environmental requirements (such as increasing air supply temperature) or adopting alternative cooling solutions (such as using natural cooling sources).
The second is to increase air conditioning efficiency: including more reasonable air flow and air conditioning maintenance management.
By using the back system, air conditioning cold air is sent directly into the cabinet to avoid cold environment and cold equipment, which can significantly improve the cooling efficiency of air conditioning.
At present a lot of IDC data room's redundant power supply system, the system will cause a certain amount of energy consumption and waste, so be reasonable layout electrical equipment according to equipment power consumption and user needs, and formulate the best layout, reduce energy consumption, and take corresponding measures to improve energy efficiency;
The heat and heat devices in the IDC room are not matched by one.
Improper room layout and cabinet heat dissipation will affect the safety of the machine room, and also reduce the cooling efficiency of the machine room and increase the energy consumption of the whole machine room.
In order to improve the temperature field, the air conditioning can be added to the air conditioner.