Alert Monitoring system, science and technology change life, the development of science and technology make our life more rich, data center machine room Monitoring system can also be referred to as the "self Monitoring system", mainly for all the equipments and environment centralized Monitoring and management, machine room Monitoring object composition of each subsystem: dynamic system, environment system, fire-fighting system, security system, network system, etc., by collecting data center computer room Monitoring systems operate a variety of data parameters to judge whether an exception, so that the operations of the personnel to make positive and accurate judgment, so the Monitoring and control system for a data center room is particularly important.
Data center machine room monitoring system is contains various, rather than a simple video monitoring, when there is some hidden trouble data center machine room, through the monitoring system found in time, it can be dangerous in the bud, in theory, any place in the data center machine room, any running system has a problem, whether monitoring system can completely cover will be in a certain extent determines the operation stability of the data center room, any one data center machine room monitoring system, the difference only lies in the improvement of the monitoring system for degree, a data center room before put into operation, needs for data center room work well after the monitoring and control system, the following steps in the data center room three important monitoring system, and in the high quality of the data center machine room, what are the little-known feature in the monitoring and control system.
(1) "equipment monitoring system" of data center machine room
Tens of thousands of data center room in the equipment, to monitor the operation of the equipment is very necessary, CPU memory parameters, such as the server is running flow of port network equipment, business level monitoring etc., equipment level monitoring is more complex, the need to compare the various operation parameters of the equipment is clear, therefore the monitoring system of general equipment use the equipment manufacturer to provide standard of monitoring software or third-party software to manage.
(1) through these monitoring software, 7*24 hours are monitored for various parameters running in the equipment, and alarm is issued once an abnormality is found.
(2) there are more alarms, which can be printed to the log host, which can be sent to the mobile phone of the operation and maintenance personnel via SMS, and can be repaired by the software system itself.
(3) monitoring software is perfect will determine fault occurs, can give the alarm, so monitoring is often involved in equipment in the process of constantly improve, a lot of monitoring parameters are the way of experience, and even the lessons of history, only by constantly improve and optimize the risk of occurrence in a timely manner, found that, of course, to do all of the fault can predict in advance, found that is very difficult.
(4) sometimes there may be no signs of failure, especially hardware failure, which will suddenly appear, and the monitoring system is unable to detect the hardware level and components failure.
(2) "video monitoring system" of data center machine room
Like other business buildings, the data center machine room also needs to deploy video monitoring system.Video monitoring is mainly to monitor access to data center room personnel, in the data center room entrances to deploy cameras, within the data center room corridor, important room entrance to deploy.
In some very important business room, sometimes to deploy the camera, in order to prevent some malicious operation or wrong operation, found that the anomalies in time to stop, to prevent affect business data center room.Many of the equipment and instruments in the data center machine room are very expensive, because of the man-made causes of damage is very common, and also to prevent some theft.For example, the light module in the computer room of the data center, a light module, especially the 40G/100G light module, will cost thousands of yuan, and take out a few of them by hand, which will make a profit of tens of thousands of yuan.
A video monitoring system, can maximum limit to avoid these behaviors, or after a surveillance video can through these analysis, accountability, and these video footage is important evidence, so the video surveillance system is an indispensable part of data center machine room, some of the data center room in addition to the video monitoring, but also in the data center room in and out to do a good job of staff access to register and manage the external personnel, avoid into some malicious molecules.
(3) "smoke temperature and humidity monitoring system" of data center machine room
The data center machine room is just as afraid of fire, once the fire is in the data center machine room is a devastating blow.There have been some painful lessons in the past, so it is not easy to set fire to the data center.The data center machine room is different from other buildings. There are too many electronic devices inside, which are not suitable for spray system. Only dry powder or inert gas can be used to extinguish fire.
When the concentration of smoke in the room than the set alarm threshold, the trigger monitor system, timely will fire the removal, in addition to smoke, the temperature and humidity inside the room is also a need to monitor the important deployment.Data center room inside to try to keep constant temperature and humidity, but in fact there will be local temperature within the data center room corner, in the past for a long time can greatly reduce the service life of electronic devices, through the deployment of many areas within the data center room temperature and humidity sensors, establish the temperature and humidity monitoring network, local area can be found in a timely manner too wet, too warm, where some of the more serious air pollution can also be deployed air cleanliness monitoring equipment, data center room equipment running in a heavily polluted environment, easy to cause the electrostatic breakdown, capacitance devices such as fault, why should we request data center computer room equipment periodically to remove dust, that is the reason why itself contains a lot of pollutants in the dust.
Data center room in the high speed development, various new technologies emerge in endlessly, also let the data center room operation becomes more complex, it also poses a challenge to monitoring system, how to timely detection by monitoring the system operating risks, monitoring system is the eternal topic of concern.
Although there are all kinds of data center computer room monitoring system, but what is certain is cannot be found in advance all the fault monitoring system, especially the level of equipment fault, but through the perfect monitoring system can greatly avoid a lot of trouble.Even if the monitoring and control system in the event of a failure, give the alarm, but in the later fault analysis, monitoring and control system of various technical parameters and the record is still available for analysis of important information, based on the monitoring record is likely to find out the cause of the failure.The role of monitoring and control system is the historical experience and lessons into some of the data parameter, and then collect data comparing various data information center machine room, if discovery is unusual, will give the alarm in time.The richer the data, the more powerful the monitoring system will be.
Conclusion:
Don't assume that a data center room is not deployed to monitor system can rest easy, any system vulnerabilities, and is the monitoring and control system, so the data center room operations staff in daily work, even more than checks and analysis, found hidden danger in time, if failed to find the monitoring system, then to find a way to add the judgment of the hidden danger to the monitoring and control system, make the monitoring system is more and more perfect, must not be allowed the same mistakes, make two consecutive times.