The importance of the UPS system to the data center

UPS system, for the data center, in the operation of the power system, the inevitable failure. Although the probability of the failure is very small and the duration is not long, the consequences are often very serious. When a power system fails, the state of operation will undergo a dramatic change. So the application of UPS system is particularly important for the uninterrupted operation of the power system of the machine room. The daily inspection and maintenance of UPS system is also the most important.
 UPS
UPS detection and maintenance
Regular inspection and maintenance of computer room is the most effective way to reduce the occurrence of the accident, the accident is an important link to reduce the battery room, UPS power supply, PDU power distribution cabinet cabinet temperature detection of appropriate professional testing tools, including battery tester, infrared temperature tester, resistance tester, tester using computer professional can provide professional data, so as to update the UPS battery power distribution cabinet and the switch, can effectively reduce the incidence of accidents.
The importance of UPS battery
UPS power is the power of many rooms that ensure the continuity of supply, to ensure the safety of the power supply system, UPS power always plays a significant role, is an important part of the UPS battery, the battery as the power supply security finally, no doubt is the last line of insurance in UPS power supply, its quality whether UPS is directly related to the normal work. According to the survey, analysis of UPS power supply can not be normal by accident, which has more than 50% accidents are caused by the faults of the battery, the battery is part of a UPS power supply high rate of accidents, thus the necessity and urgency of improving the safe and reliable operation of the battery.
Hidden danger of UPS battery safety
1., battery life can not meet the design requirements. In practical applications, batteries often begin to deteriorate after 1 years of use. The deterioration of batteries over 3 years is very serious, and almost no capacity can achieve nominal capacity. There are two aspects, one is to predict battery manufacturers under ideal conditions for the service life of the battery; second, in use for the maintenance and management of battery, there is no effective, resulting in deterioration of the battery early, not detected, resulting in deterioration of accumulation, increased the cumulative losses lead to battery capacity, scrapped prematurely.
2. the charge and discharge of the battery is not recorded and monitored, and the operation of the battery is unknown.
3., due to the lack of good means and management, the users of the battery do not know enough about the operation of the battery, especially for sorting out and analyzing the history data of the battery. The collation and analysis of these data needs strong professional knowledge.
4. the performance of the battery is unknown, especially if the UPS battery has an instant power supply capability.
5. the performance of the battery, such as the voltage balance of the battery and the current capacity, can not be understood in real time.
6. the lack of temperature compensation and environmental temperature monitoring.
7.UPS battery is lack of detection means and maintenance instruments, and the degree of attention is insufficient.