Datacenter migration,When the enterprise develops to a certain extent, or the former computer room can not satisfy the current data center, the enterprise will migrate the data center. Data center migration is simple, but if you really do it, you will find that data center migration is a complex project.
It is more difficult to move the data center safely, because when the data center is migrated, there are some risks that can not be avoided, but we can take some measures to reduce the risk of data center migration.
What risks do you encounter when migrating in a data center? What measures should we do to avoid these risks? Let's analyze the problems and risks associated with the management of the data center.
1. data migration
Migrating application data from one place to another may be one of the most complex aspects of data center migration engineering. A simple solution is to perform backup based on tape or hard disk and perform recovery; however, similar translation migration, backup and recovery are limited in the ability to provide timely recovery services. In addition, backup and recovery is not the most ideal method for data migration -- it is more suitable for disaster recovery scenarios with limited data recovery.
2. hardware migration
There are usually two strategies for migrating physical servers: one is "translation" and another is data replication. In the translation strategy, the hardware is put on the moving truck and installed in the new data center. The system has been backed up before moving to the new site, but this strategy poses some risks.
One of the biggest risks is that the physical server may be damaged during the handling process, and the damage during transportation will result in backups useless. Another challenge is that the two data centers are too far apart, so this method is unrealistic and can not guarantee that services can be used in acceptable time periods.
The second strategy is to transfer data through a leased line. Leased lines bring two kinds of sub-swing hardware solutions. One solution is to implement physical machine to physical machine (P2P) migration. P2P migration requires the acquisition of similar hardware, so that the application and hardware of the original data center can be migrated in the past, while ensuring the shortest downtime.
3. service availability
The main purpose of data centers is to host applications running to provide services for business. Whenever you consider moving from one data center to another, you must first consider the availability of the underlying services. These services include infrastructure applications such as active directory and client oriented applications such as SAP.
When a service is transferred from one data center to another, you have to formulate a strategy that must be taken into consideration when a specific service is migrated and the application is dependent on each other. A common way to ensure service availability is to set up the migration group and then divide the interdependent applications into the same group. As for services that support most business applications, such as active directory and DNS, a common practice is to extend these core services across data centers. The service is still in the data center on both sides until the migration is completed.
The migration data center is an important and complex project for the enterprise, and the successful migration of the data center is also very important for the enterprise. So, some security risks that will be encountered during the migration process, and the enterprise should make the corresponding measures in time.
2018年7月22日 星期日
Company website design a problem that must be paid attention?
Website design is the facade of the company in the virtual network market, and it is also an indirect embodiment of product service quality. If a company's Web site is very rough, it is an indirect reflection of the impression that the company is careless, the working attitude is not strict and careful, and then the product or service is not good. With such psychological hints, it is difficult for customers to have enough motivation to take the initiative to contact and negotiate business. Therefore, we must pay attention to the following six problems when we build the company website.
1. No keyword analysis was carried out before the design of the website
If the company web page design does not properly analyze the key words, it will cause a lot of problems, such as the direction is not clear, the key word configuration is not reasonable, the ranking effect is poor and ROI low and so on, so we must first analyze the key words.
2. The company's website is designed to pursue the beauty of the website
Some websites only pursue beauty: atmosphere, good-looking and beautiful. In fact, these are not necessary for company website construction. Users like simple and clear pages, so as to bring a good visual experience.
Instead of using a large number of pictures and too much flash to make the site look more sophisticated, it will cause a large volume of pages and slow page loading, which greatly reduces the usability of the web site. Nor do you want to use pictures as links in navigation, which makes it difficult for search engines to identify web sites.
3. Lack of import links after the design of the web site
Many website construction optimization problems exist, check it is not difficult to find, many are due to the lack of import links. In the Internet, the relationship between web pages and web pages is established through links. If there is no link between the web and the outside world, there is no connection, it becomes an island type website, and the search engine can not know the existence of the website.
4. Direct copy of reference web site when web site design
In order to save money and labor, a lot of people are trying to use their moustache brows in the company website construction, and directly use the existing website program DEDEhome template. This new station will be very similar to the previous station, which will lead to a new ranking of the new station, and the old station will also be affected.
5. Frequently change the title of the web page when the web site is optimized
The company's website design search engine relies on title tags for segmentation and indexing, which is the core of the search engine rankings at the initial stage. Although it has developed rapidly from the technical point of view, the dependence on title is still a key point to improve the user experience. If the title is changed, the search is a key point. The engine will treat it as cheating, so be careful when changing title.
6. A large number of articles are collected during the operation of the website
Search engines do not give a good ranking of highly repetitive articles on the Internet. If a large collection of articles is included on the website, it will have a negative impact on the website. If the company website design, if there is no or only a few original substance, it will bring bad browsing experience to the users, and will leave a bad impression on the search engine, and bring difficulties for the search engine optimization.
1. No keyword analysis was carried out before the design of the website
If the company web page design does not properly analyze the key words, it will cause a lot of problems, such as the direction is not clear, the key word configuration is not reasonable, the ranking effect is poor and ROI low and so on, so we must first analyze the key words.
2. The company's website is designed to pursue the beauty of the website
Some websites only pursue beauty: atmosphere, good-looking and beautiful. In fact, these are not necessary for company website construction. Users like simple and clear pages, so as to bring a good visual experience.
Instead of using a large number of pictures and too much flash to make the site look more sophisticated, it will cause a large volume of pages and slow page loading, which greatly reduces the usability of the web site. Nor do you want to use pictures as links in navigation, which makes it difficult for search engines to identify web sites.
3. Lack of import links after the design of the web site
Many website construction optimization problems exist, check it is not difficult to find, many are due to the lack of import links. In the Internet, the relationship between web pages and web pages is established through links. If there is no link between the web and the outside world, there is no connection, it becomes an island type website, and the search engine can not know the existence of the website.
4. Direct copy of reference web site when web site design
In order to save money and labor, a lot of people are trying to use their moustache brows in the company website construction, and directly use the existing website program DEDEhome template. This new station will be very similar to the previous station, which will lead to a new ranking of the new station, and the old station will also be affected.
5. Frequently change the title of the web page when the web site is optimized
The company's website design search engine relies on title tags for segmentation and indexing, which is the core of the search engine rankings at the initial stage. Although it has developed rapidly from the technical point of view, the dependence on title is still a key point to improve the user experience. If the title is changed, the search is a key point. The engine will treat it as cheating, so be careful when changing title.
6. A large number of articles are collected during the operation of the website
Search engines do not give a good ranking of highly repetitive articles on the Internet. If a large collection of articles is included on the website, it will have a negative impact on the website. If the company website design, if there is no or only a few original substance, it will bring bad browsing experience to the users, and will leave a bad impression on the search engine, and bring difficulties for the search engine optimization.
2018年7月19日 星期四
機房建置,論數據中心技術複雜性
機房建置,在常人眼中,數據中心不過是一座擺放了成千上萬臺設備的普通建築,只要有資金,有人力,誰都可以建造上幾座。而實際上,一個數據中心的複雜度遠超人們想象,是“貧窮限制了想象力”。
數據中心幾乎將世界上最先進的信息技術都集成了起來,在這裏涉及到動力,製冷,通風,建築,網絡,計算,存儲,佈線,消防,監控等等十幾個技術門類,覆蓋到數十項學科的先進技術。現在很多的雲計算,大數據,人工智能,軟件定義也都是在數據中心裏大放異彩,數據中心是這些先進技術的實踐土壤,都要到數據中心來走一遭,只有經過數據中心考驗的技術纔是真正的技術,能夠得到業界認可的技術。
關於數據中心,維基百科給出的定義是“數據中心是一整套複雜的設施。它不僅僅包括計算機系統和其它與之配套的設備,還包含冗餘的數據通信連接,環境控制設備,監控設備以及各種安全裝置”。這個定義還不夠全面,幾乎沒有哪個定義能夠將數據中心概括清楚,因爲數據中心實在是太複雜了,並非用幾個詞語或者幾句話就能概括清楚。當然,並不是一開始數據中心就很複雜,在最開始我們甚至可以將擁有幾臺電腦的機房也可以叫做數據中心,但數據中心規模和技術都發展太快,複雜性呈幾何性增長,我們討論數據中心的複雜性都是基於當前現狀來討論的。
首先,數據中心規模增長迅速,原來佔地幾千平米的大型數據中心,放到現在也就屬於中小型數據中心,現在的數據中心動輒10萬服務器,要將這些服務器都放滿就得多大的建築空間,這還不包括網絡,通風和製冷等其它不可缺少的系統。一旦規模上來,所有的系統都需要適配,這個複雜不是簡單地累加,而是幾何倍數的增長,比如建造大樓,建設一座50層的大樓和120層的大樓成本可不是增長兩倍的關係,假如建設50層大樓,平均下3000來元一平,10萬平米就是3個億.120層的話,造價應該是50層樓的10倍,萬3元一平,如果是30萬平方米,那就是90個億,整整差了87個億。
其次,數據中心是一個多功能的建築物,並不僅僅是一些服務器的集合,要將這些服務器互聯互通起來,並且讓運行的應用軟件平穩運行,需要做大量系統設計工作,每個設備裏跑的每一條指令都有其特定的意義。我們知道僅僅以太網的RFC就有八千多篇了,沒有人能將所有網絡協議都搞懂,但卻要在數據中心裏部署很多網絡協議,複雜度可想而知。登錄到任意一臺網絡設備,都能看出至少上百行的網絡配置,多的有上萬行,這裏的每一條配置指令都是爲整個數據中心運行服務的,不可缺少,任何一個局部微小的操作都可能導致全局業務受損,爲何要建設自動化運行的數據中心,其實有一個重要的原因就是靠人的經驗去管理數據中心已經不可能了,只能靠機器自動管理。
第三,新技術演進太快,雲計算也不過才十年之久,就已經遍地開花了,大數據,人工智能甚至區塊鏈都來了,這些技術的寄託都是在海量數據上,哪裏有海量數據,就是數據中心。還有5 g,移動互聯網,物聯網等等,哪個能離開數據中心?數據中心真是一專多能,海納百川,無所不能,這些應用都給數據中心提出了新的挑戰,數據中心的基礎設施要能滿足這些應用,只能不斷變化調整,系統愈發複雜。
第四,人們對數據中心要求越來越高,現在的數據中心全年都不能中斷,每中斷一分鐘都會影響業務,因爲很多互聯網業務是24小時的都有人訪問,前幾天阿里雲中斷一個小時,全網一片譁然,阿里雲也及時坦誠不公地進行了道的歉。這種事情再一再二可以,不能再三再四了,反覆多次的故障很容易導致大量用戶流失,最終只能關門大吉,所以數據中心提供持續無中斷的能力看得比命都重要,如此必然要在數據中心的各個系統中做冗餘備份設計。
冗餘備份設計給數據中心帶來的就是增加複雜性,冗餘做的越多,複雜性越高,看似安全,實則危險重重。過於複雜的系統運行起來不僅效率低,甚至在故障出現時,根本無法快速準確定位,所以要在冗餘和複雜性之間做取捨,選擇上做好平衡。
所以,數據中心不僅包含很多系統,每個系統還都很複雜的,越來越複雜,真是“貧窮限制了想象力”。現在哪個大型數據中心不是要靠幾十人的運維團隊才能支撐,這是一項龐大的費用支出,而且還並不能保證支持好,數據中心涉及那麼多學科技術,一個人完全掌握一項都不得了,怎麼可能都掌握到。數據中心每天要疲於處理各種各樣的問題:應用需求,擴容,變的更,升級等等,複雜性增加了這裏的每一項工作,要想一點錯不出很困難,這也就不難想象一個數據中心百分之八十的故障都來自人爲。
這麼複雜的系統,沒有誰能夠有百分之百的把握操作能達到預期效果,不出意外。如果我們再一味這樣,將數據中心按如此的方式,不斷建造下去,數據中心複雜性遲早會達到人們無法想象,無法管控的階段,讓數據中心陷入無序,這樣再好的技術也是白搭。數據中心複雜性已經引起了更多人的關注,很多專家和學者也在出謀劃策,給出了一些超融合解決方案,試圖減輕數據中心負擔。現在的數據中心必須做減法,要化繁而簡,不能再去一味追求規模,新技術的引入也不能增加系統複雜性,控制好數據中心複雜度,以免失控。
數據中心幾乎將世界上最先進的信息技術都集成了起來,在這裏涉及到動力,製冷,通風,建築,網絡,計算,存儲,佈線,消防,監控等等十幾個技術門類,覆蓋到數十項學科的先進技術。現在很多的雲計算,大數據,人工智能,軟件定義也都是在數據中心裏大放異彩,數據中心是這些先進技術的實踐土壤,都要到數據中心來走一遭,只有經過數據中心考驗的技術纔是真正的技術,能夠得到業界認可的技術。
關於數據中心,維基百科給出的定義是“數據中心是一整套複雜的設施。它不僅僅包括計算機系統和其它與之配套的設備,還包含冗餘的數據通信連接,環境控制設備,監控設備以及各種安全裝置”。這個定義還不夠全面,幾乎沒有哪個定義能夠將數據中心概括清楚,因爲數據中心實在是太複雜了,並非用幾個詞語或者幾句話就能概括清楚。當然,並不是一開始數據中心就很複雜,在最開始我們甚至可以將擁有幾臺電腦的機房也可以叫做數據中心,但數據中心規模和技術都發展太快,複雜性呈幾何性增長,我們討論數據中心的複雜性都是基於當前現狀來討論的。
首先,數據中心規模增長迅速,原來佔地幾千平米的大型數據中心,放到現在也就屬於中小型數據中心,現在的數據中心動輒10萬服務器,要將這些服務器都放滿就得多大的建築空間,這還不包括網絡,通風和製冷等其它不可缺少的系統。一旦規模上來,所有的系統都需要適配,這個複雜不是簡單地累加,而是幾何倍數的增長,比如建造大樓,建設一座50層的大樓和120層的大樓成本可不是增長兩倍的關係,假如建設50層大樓,平均下3000來元一平,10萬平米就是3個億.120層的話,造價應該是50層樓的10倍,萬3元一平,如果是30萬平方米,那就是90個億,整整差了87個億。
其次,數據中心是一個多功能的建築物,並不僅僅是一些服務器的集合,要將這些服務器互聯互通起來,並且讓運行的應用軟件平穩運行,需要做大量系統設計工作,每個設備裏跑的每一條指令都有其特定的意義。我們知道僅僅以太網的RFC就有八千多篇了,沒有人能將所有網絡協議都搞懂,但卻要在數據中心裏部署很多網絡協議,複雜度可想而知。登錄到任意一臺網絡設備,都能看出至少上百行的網絡配置,多的有上萬行,這裏的每一條配置指令都是爲整個數據中心運行服務的,不可缺少,任何一個局部微小的操作都可能導致全局業務受損,爲何要建設自動化運行的數據中心,其實有一個重要的原因就是靠人的經驗去管理數據中心已經不可能了,只能靠機器自動管理。
第三,新技術演進太快,雲計算也不過才十年之久,就已經遍地開花了,大數據,人工智能甚至區塊鏈都來了,這些技術的寄託都是在海量數據上,哪裏有海量數據,就是數據中心。還有5 g,移動互聯網,物聯網等等,哪個能離開數據中心?數據中心真是一專多能,海納百川,無所不能,這些應用都給數據中心提出了新的挑戰,數據中心的基礎設施要能滿足這些應用,只能不斷變化調整,系統愈發複雜。
第四,人們對數據中心要求越來越高,現在的數據中心全年都不能中斷,每中斷一分鐘都會影響業務,因爲很多互聯網業務是24小時的都有人訪問,前幾天阿里雲中斷一個小時,全網一片譁然,阿里雲也及時坦誠不公地進行了道的歉。這種事情再一再二可以,不能再三再四了,反覆多次的故障很容易導致大量用戶流失,最終只能關門大吉,所以數據中心提供持續無中斷的能力看得比命都重要,如此必然要在數據中心的各個系統中做冗餘備份設計。
冗餘備份設計給數據中心帶來的就是增加複雜性,冗餘做的越多,複雜性越高,看似安全,實則危險重重。過於複雜的系統運行起來不僅效率低,甚至在故障出現時,根本無法快速準確定位,所以要在冗餘和複雜性之間做取捨,選擇上做好平衡。
所以,數據中心不僅包含很多系統,每個系統還都很複雜的,越來越複雜,真是“貧窮限制了想象力”。現在哪個大型數據中心不是要靠幾十人的運維團隊才能支撐,這是一項龐大的費用支出,而且還並不能保證支持好,數據中心涉及那麼多學科技術,一個人完全掌握一項都不得了,怎麼可能都掌握到。數據中心每天要疲於處理各種各樣的問題:應用需求,擴容,變的更,升級等等,複雜性增加了這裏的每一項工作,要想一點錯不出很困難,這也就不難想象一個數據中心百分之八十的故障都來自人爲。
這麼複雜的系統,沒有誰能夠有百分之百的把握操作能達到預期效果,不出意外。如果我們再一味這樣,將數據中心按如此的方式,不斷建造下去,數據中心複雜性遲早會達到人們無法想象,無法管控的階段,讓數據中心陷入無序,這樣再好的技術也是白搭。數據中心複雜性已經引起了更多人的關注,很多專家和學者也在出謀劃策,給出了一些超融合解決方案,試圖減輕數據中心負擔。現在的數據中心必須做減法,要化繁而簡,不能再去一味追求規模,新技術的引入也不能增加系統複雜性,控制好數據中心複雜度,以免失控。
Datacenter migration more effective cooling methods are needed
Datacenter migration, today's data centers are changing rapidly, and it is clearly more important than ever to ensure that every component that supports the infrastructure can run with maximum efficiency and reliability.Failure of key cooling systems in data centers can lead to downtime and loss of business services, capital and customer goodwill.
Data center cooling systems typically receive less attention than servers, operating systems, and network configurations.However, the performance of these IT systems depends as much on cooling support as on network connectivity.
Precision cooling system is designed to meet the demand of data center thermal load. It has very different service and maintenance requirements compared with the general standard building air-conditioning designed for cool comfort.
However, to maximize the performance and efficiency of precision cooling systems, proper maintenance needs to be done by the original equipment manufacturer (OEM) with trained and certified technicians.Trained technicians have extensive knowledge of how to implement maintenance to support key systems in data centers.Integrating cooling systems into the data center infrastructure support strategy is critical, and most non-manufacturing maintenance practices lack this experience.
1. Changes in current data center cooling
The critical nature of IT equipment and the unique environment that supports its operations require the use of dedicated precision cooling systems at data center sites.Since most data centers operate 24 by 7 by 365 throughout the day, their temperature and humidity conditions must also ensure a stable level throughout the day.
Sophisticated systems are designed to cool electronic equipment.The electronic equipment produces pure sensible heat, which has no humidity and needs continuous cooling.General air conditioners designed to provide comfort are not suitable for these types of conditions.
Computers generate heat, but not humidity
That's why about 95 percent of the energy and capacity of sophisticated cooling systems is designed to remove the dry heat produced by electronics.The cooling and cooling systems of general buildings are designed to provide people with a comfortable feeling, so only about 60% of the cooling capacity is used to eliminate the heat generated by computers.In addition, 40 percent of the cooling capacity is used to remove water that normally exists in the office environment, a requirement that does not exist in the server room or network room.Excessive humidity reduction may lead to electrostatic problems or even electronic failures.
Servers and other IT devices are often designed to operate in environments that maintain a range of temperature and humidity.Exceeding these conditions can lead to performance degradation and shorten the service life of the device.
Because precision cooling systems are designed to operate continuously, their service requirements are much more stringent than those for comfortable cooling alone.It requires maintenance at greater intervals, especially for motor lubrication and other moving parts.
Precision cooling also requires humidification, which involves another set of maintenance procedures.This is crucial because electronic devices require stable moisture levels.Improper humidity levels can actually cause processor slowdowns or electrostatic problems.
Non-oem service providers may not be familiar with maintaining this type of humidification equipment.If a unit has a humidifier to reduce potential condensate emissions and fills the entire computer room, more frequent maintenance may be required.
The service people involved must look at many things and know and understand many things at the same time.This is also true for the service requirements and expertise required to perform such maintenance because precision refrigeration is very different from comfortable air conditioning systems.
Higher density means higher thermal load
In recent years, many changes have taken place in the cooling requirements of data centers and the functions that affect operations.The most important of them is the increase of thermal load density of new technology IT equipment and the increase of thermal load.Higher density thermal loads require more complex cooling techniques.
However, with the implementation of high-density rack configuration and deployment, the original data center with the traditional precise cooling configuration is used to deliver air to the air conditioning (CRAC) unit of the large computer room under the overhead floor, which may encounter some bottleneck problems.Due to the lack of cooling capacity in some high density areas, hot spots may occur.The typical underfloor exhaust may not be enough to cool these hot spots.If the auxiliary cooling is not used, the frame with load higher than 4 ~ 5 kW will be vulnerable to hot spots.
4. Increase of thermal load of data center
Even though high cooling capacity may exist in the data center machine room, if the cooling system fails, the distribution of cooling air may cause corresponding problems.Elevated floor configurations are not always designed for optimal air flow.They may be running so close to the edge of capacity that any downtime due to maintenance problems can cause problems.
The solution to these problems is to use rack - based cooling and other target cooling systems.Key cooling technologies are developing into integrated solutions based on computer rooms and networks, not just on individual HVAC units.These different types of systems require high-level service technicians with an in-depth understanding of their operations.
V. more complex cooling methods
Precision air conditioning USES a wide range of cooling media and requires professional maintenance technicians with relevant knowledge to adjust control and test systems.These cooling methods include air, chilled water and refrigerants.In most cases, these systems are more complex than general comfort cooling systems and require more attention to maintenance to provide optimal performance.
Unique energy-saving configurations such as dual cooling systems are becoming more and more popular as a way to save energy.With this option, traditional air cooling units are converted to a dual source cooling system by adding a second coil supplied by a central building cooler.The unit can be used either as a chilled water system, as a compression system, or as a combination of both.When the coolers are available, compressor operations are eliminated, reducing energy costs.
A more efficient energy saving solution in a cold climate is the combination of an outdoor fluid cooler (dry cooler and pump unit) with a chilled water coil conversion, which provides "free cooling" when the ambient temperature permits.In this case, the cooling load will not be transferred to the chiller under peak load operating conditions.
However, it is essential to operate and inspect all components of these systems on a regular basis to ensure that they are ready when needed.This requires an experienced service technician familiar with all aspects of precision cooling to serve these complex systems.
New equipment requires a new set of skills
The new generation electronic control system improves efficiency by coordinating and optimizing the operation of various cooling units in the data center.These control systems, of course, require more expertise to implement maintenance and services.Untrained equipment service personnel may actually cause the cooling system to fail in an attempt to perform adjustment or maintenance.
The new chilled water units with advanced control systems and variable frequency drives are very different from previous models.The use of advanced control systems requires well-trained service professionals.Untrained maintenance personnel, who perform routine maintenance on these types of control systems, may invalidate the warranty of the equipment.
Digital scroll compressor, using advanced electronic control and modulation to achieve more efficient operation.However, the operation of a digital vortex unit is different from that of a standard scroll compressor.The maintenance technician trained by the equipment supplier knows how to correctly diagnose the potential problems of compressor and how to carry out daily maintenance.
The unique aspect of precision cooling affects service demand
The differences between today's sophisticated data center cooling systems and those that generally provide comfort have created very different maintenance requirements in order to maintain the normal and efficient operation of data center equipment.Proper maintenance of precision cooling systems throughout their lifetime is undoubtedly important: if the precision cooling system in a data center cannot operate at its highest level, it cannot benefit the data center completely.
For example, a non-oem service source may not fully understand the complexity of cooling under the floor.The migration of IT equipment and the movement of perforated tiles that transport cooling air to the service area machine room may result in inefficient implementation of cooling equipment.Improper positioning of perforated tile may even lead to short circulation of compressor.
Humidity in the machine room may be affected by maintenance problems.Dirty air filters can affect humidity levels by acting like sponges and absorbing water.Once the clean air is fed through the filter, humidity levels can be restored to their optimum levels.Service personnel must also be able to implement other adjustments including humidifier panels and drain pipes.
The ability to make proper set-point adjustments is also important for the operation of precision cooling systems.It depends on the size of the room and how the heat load is distributed.
If the drain pipe from the evaporator coil is blocked, condensate water problem will occur, resulting in water overflow.Condensate deposited on the coil can also cause impurities to accumulate.Periodic inspection is required whether the pump or gravity drain is used for condensing water or not.If the humidifier drainage is not maintained properly, steam from the humidifier may cause moisture problems.A lack of adequate air flow through these cells may result in a buildup of condensation within the unit.
The use of forward/backward running cooling units is becoming standard practice.The cell network helps with this setup and helps prevent one cell from operating more frequently than another, causing maintenance problems.
A leak detection system is another unique element of a data center.These systems need to be checked regularly to make sure they work properly.
Service personnel trained professionally by equipment vendors know what to look for on these types of systems to prevent any problems.
The manufacturer's engineering changes, including component rework and recall, were also immediately communicated to maintenance personnel trained by the equipment manufacturer.So that they can also access any product upgrades or changes immediately.Not knowing about these updates can lead to too many replacement parts or other problems.
Service providers also need to be familiar with the types of oils and refrigerants used in precision units.Changes in the type of refrigerant used over the past few years have highlighted the importance of proper maintenance and treatment in this area.
Better equipment manufacturer training and certification services
While non-oem service providers may have the knowledge required to install precision cooling equipment, they may not necessarily have the service expertise required to ensure the best performance of these systems after installation.
The level of knowledge required to maintain a comfortable cooling system in a standard building is different from that required for an accurate cooling system in a data center.
The service technicians supported by the manufacturer are professionally trained to handle all aspects of the service.They have the knowledge and experience needed to identify areas of concern where data centers can cause problems in cooling units.
The proper functioning of a data center is critical.Technicians trained by equipment manufacturers have the resources to quickly access key service components.This access allows these technicians to quickly bring disabled units back online with minimal disruption.
Comparison of precision air conditioning and comfortable air conditioning
Unlike a comfortable cooling service, service maintainers are not allowed to leave the data center at night during maintenance and return to work the next day.The maintenance technician's goal is to minimize downtime for the unit.At the data center site, technicians can work on other units to ensure efficient operation of the data center.
OEM based services are also professionally trained to provide up-to-date software and firmware installation to help ensure proper control.Complete firmware upgrade knowledge will ensure that precision refrigeration units operate at maximum efficiency.Only maintenance technicians trained by the OEM factory can access and execute the knowledge required for these software/firmware changes.
OEM factories provide all-weather emergency services and preventive maintenance for precise cooling systems.In most cases, the service staff supported by the OEM factory can reach the data center site in about half the time required for other service providers.The service is available 24/7 in emergencies.
As a trained technician supported by an OEM factory, I have obtained differentiated service product design to help enterprise customers improve performance and energy efficiency.These include enterprise remote monitoring, control networks/upgrades, thermal assessment and computational fluid dynamics modeling.
10. Data center cooling assessment to track changing requirements
With the development and change of data center, precision cooling system will develop continuously.To ensure the best performance of the cooling system, this evolution should follow the relevant indicators collected by the service provider during the thermal assessment.
Understanding the performance of the data center cooling system is the key to planning proper maintenance.Customers need to evaluate the cooling performance of their data centers during peak capacity operation to truly understand their cooling needs.
This type of detailed analysis is the key to optimizing data center cooling.This level of research requires people with the tools to determine where the hot spots are and how to correct them.
Different types of cooling require different services
Because precise cooling systems are designed in a way that makes them very different from the comfort air conditioning of a typical building, service providers without specific knowledge of how to maintain equipment may not be ready to handle the work.Inexperienced service providers greatly increase the risk of equipment delivery failures, and service providers trained with OEM factories help ensure accurate cooling systems operate at their best performance and efficiency points.
The continuous operation of precision cooling is necessary for the normal operation of data center IT equipment.This makes its maintenance extremely important.It also makes no sense to use services from service providers that may not have the expertise to maintain their performance levels, or to potentially undermine investment in precision air conditioning in enterprise data centers.
Data center cooling systems typically receive less attention than servers, operating systems, and network configurations.However, the performance of these IT systems depends as much on cooling support as on network connectivity.
Precision cooling system is designed to meet the demand of data center thermal load. It has very different service and maintenance requirements compared with the general standard building air-conditioning designed for cool comfort.
However, to maximize the performance and efficiency of precision cooling systems, proper maintenance needs to be done by the original equipment manufacturer (OEM) with trained and certified technicians.Trained technicians have extensive knowledge of how to implement maintenance to support key systems in data centers.Integrating cooling systems into the data center infrastructure support strategy is critical, and most non-manufacturing maintenance practices lack this experience.
1. Changes in current data center cooling
The critical nature of IT equipment and the unique environment that supports its operations require the use of dedicated precision cooling systems at data center sites.Since most data centers operate 24 by 7 by 365 throughout the day, their temperature and humidity conditions must also ensure a stable level throughout the day.
Sophisticated systems are designed to cool electronic equipment.The electronic equipment produces pure sensible heat, which has no humidity and needs continuous cooling.General air conditioners designed to provide comfort are not suitable for these types of conditions.
Computers generate heat, but not humidity
That's why about 95 percent of the energy and capacity of sophisticated cooling systems is designed to remove the dry heat produced by electronics.The cooling and cooling systems of general buildings are designed to provide people with a comfortable feeling, so only about 60% of the cooling capacity is used to eliminate the heat generated by computers.In addition, 40 percent of the cooling capacity is used to remove water that normally exists in the office environment, a requirement that does not exist in the server room or network room.Excessive humidity reduction may lead to electrostatic problems or even electronic failures.
Servers and other IT devices are often designed to operate in environments that maintain a range of temperature and humidity.Exceeding these conditions can lead to performance degradation and shorten the service life of the device.
Because precision cooling systems are designed to operate continuously, their service requirements are much more stringent than those for comfortable cooling alone.It requires maintenance at greater intervals, especially for motor lubrication and other moving parts.
Precision cooling also requires humidification, which involves another set of maintenance procedures.This is crucial because electronic devices require stable moisture levels.Improper humidity levels can actually cause processor slowdowns or electrostatic problems.
Non-oem service providers may not be familiar with maintaining this type of humidification equipment.If a unit has a humidifier to reduce potential condensate emissions and fills the entire computer room, more frequent maintenance may be required.
The service people involved must look at many things and know and understand many things at the same time.This is also true for the service requirements and expertise required to perform such maintenance because precision refrigeration is very different from comfortable air conditioning systems.
Higher density means higher thermal load
In recent years, many changes have taken place in the cooling requirements of data centers and the functions that affect operations.The most important of them is the increase of thermal load density of new technology IT equipment and the increase of thermal load.Higher density thermal loads require more complex cooling techniques.
However, with the implementation of high-density rack configuration and deployment, the original data center with the traditional precise cooling configuration is used to deliver air to the air conditioning (CRAC) unit of the large computer room under the overhead floor, which may encounter some bottleneck problems.Due to the lack of cooling capacity in some high density areas, hot spots may occur.The typical underfloor exhaust may not be enough to cool these hot spots.If the auxiliary cooling is not used, the frame with load higher than 4 ~ 5 kW will be vulnerable to hot spots.
4. Increase of thermal load of data center
Even though high cooling capacity may exist in the data center machine room, if the cooling system fails, the distribution of cooling air may cause corresponding problems.Elevated floor configurations are not always designed for optimal air flow.They may be running so close to the edge of capacity that any downtime due to maintenance problems can cause problems.
The solution to these problems is to use rack - based cooling and other target cooling systems.Key cooling technologies are developing into integrated solutions based on computer rooms and networks, not just on individual HVAC units.These different types of systems require high-level service technicians with an in-depth understanding of their operations.
V. more complex cooling methods
Precision air conditioning USES a wide range of cooling media and requires professional maintenance technicians with relevant knowledge to adjust control and test systems.These cooling methods include air, chilled water and refrigerants.In most cases, these systems are more complex than general comfort cooling systems and require more attention to maintenance to provide optimal performance.
Unique energy-saving configurations such as dual cooling systems are becoming more and more popular as a way to save energy.With this option, traditional air cooling units are converted to a dual source cooling system by adding a second coil supplied by a central building cooler.The unit can be used either as a chilled water system, as a compression system, or as a combination of both.When the coolers are available, compressor operations are eliminated, reducing energy costs.
A more efficient energy saving solution in a cold climate is the combination of an outdoor fluid cooler (dry cooler and pump unit) with a chilled water coil conversion, which provides "free cooling" when the ambient temperature permits.In this case, the cooling load will not be transferred to the chiller under peak load operating conditions.
However, it is essential to operate and inspect all components of these systems on a regular basis to ensure that they are ready when needed.This requires an experienced service technician familiar with all aspects of precision cooling to serve these complex systems.
New equipment requires a new set of skills
The new generation electronic control system improves efficiency by coordinating and optimizing the operation of various cooling units in the data center.These control systems, of course, require more expertise to implement maintenance and services.Untrained equipment service personnel may actually cause the cooling system to fail in an attempt to perform adjustment or maintenance.
The new chilled water units with advanced control systems and variable frequency drives are very different from previous models.The use of advanced control systems requires well-trained service professionals.Untrained maintenance personnel, who perform routine maintenance on these types of control systems, may invalidate the warranty of the equipment.
Digital scroll compressor, using advanced electronic control and modulation to achieve more efficient operation.However, the operation of a digital vortex unit is different from that of a standard scroll compressor.The maintenance technician trained by the equipment supplier knows how to correctly diagnose the potential problems of compressor and how to carry out daily maintenance.
The unique aspect of precision cooling affects service demand
The differences between today's sophisticated data center cooling systems and those that generally provide comfort have created very different maintenance requirements in order to maintain the normal and efficient operation of data center equipment.Proper maintenance of precision cooling systems throughout their lifetime is undoubtedly important: if the precision cooling system in a data center cannot operate at its highest level, it cannot benefit the data center completely.
For example, a non-oem service source may not fully understand the complexity of cooling under the floor.The migration of IT equipment and the movement of perforated tiles that transport cooling air to the service area machine room may result in inefficient implementation of cooling equipment.Improper positioning of perforated tile may even lead to short circulation of compressor.
Humidity in the machine room may be affected by maintenance problems.Dirty air filters can affect humidity levels by acting like sponges and absorbing water.Once the clean air is fed through the filter, humidity levels can be restored to their optimum levels.Service personnel must also be able to implement other adjustments including humidifier panels and drain pipes.
The ability to make proper set-point adjustments is also important for the operation of precision cooling systems.It depends on the size of the room and how the heat load is distributed.
If the drain pipe from the evaporator coil is blocked, condensate water problem will occur, resulting in water overflow.Condensate deposited on the coil can also cause impurities to accumulate.Periodic inspection is required whether the pump or gravity drain is used for condensing water or not.If the humidifier drainage is not maintained properly, steam from the humidifier may cause moisture problems.A lack of adequate air flow through these cells may result in a buildup of condensation within the unit.
The use of forward/backward running cooling units is becoming standard practice.The cell network helps with this setup and helps prevent one cell from operating more frequently than another, causing maintenance problems.
A leak detection system is another unique element of a data center.These systems need to be checked regularly to make sure they work properly.
Service personnel trained professionally by equipment vendors know what to look for on these types of systems to prevent any problems.
The manufacturer's engineering changes, including component rework and recall, were also immediately communicated to maintenance personnel trained by the equipment manufacturer.So that they can also access any product upgrades or changes immediately.Not knowing about these updates can lead to too many replacement parts or other problems.
Service providers also need to be familiar with the types of oils and refrigerants used in precision units.Changes in the type of refrigerant used over the past few years have highlighted the importance of proper maintenance and treatment in this area.
Better equipment manufacturer training and certification services
While non-oem service providers may have the knowledge required to install precision cooling equipment, they may not necessarily have the service expertise required to ensure the best performance of these systems after installation.
The level of knowledge required to maintain a comfortable cooling system in a standard building is different from that required for an accurate cooling system in a data center.
The service technicians supported by the manufacturer are professionally trained to handle all aspects of the service.They have the knowledge and experience needed to identify areas of concern where data centers can cause problems in cooling units.
The proper functioning of a data center is critical.Technicians trained by equipment manufacturers have the resources to quickly access key service components.This access allows these technicians to quickly bring disabled units back online with minimal disruption.
Comparison of precision air conditioning and comfortable air conditioning
Unlike a comfortable cooling service, service maintainers are not allowed to leave the data center at night during maintenance and return to work the next day.The maintenance technician's goal is to minimize downtime for the unit.At the data center site, technicians can work on other units to ensure efficient operation of the data center.
OEM based services are also professionally trained to provide up-to-date software and firmware installation to help ensure proper control.Complete firmware upgrade knowledge will ensure that precision refrigeration units operate at maximum efficiency.Only maintenance technicians trained by the OEM factory can access and execute the knowledge required for these software/firmware changes.
OEM factories provide all-weather emergency services and preventive maintenance for precise cooling systems.In most cases, the service staff supported by the OEM factory can reach the data center site in about half the time required for other service providers.The service is available 24/7 in emergencies.
As a trained technician supported by an OEM factory, I have obtained differentiated service product design to help enterprise customers improve performance and energy efficiency.These include enterprise remote monitoring, control networks/upgrades, thermal assessment and computational fluid dynamics modeling.
10. Data center cooling assessment to track changing requirements
With the development and change of data center, precision cooling system will develop continuously.To ensure the best performance of the cooling system, this evolution should follow the relevant indicators collected by the service provider during the thermal assessment.
Understanding the performance of the data center cooling system is the key to planning proper maintenance.Customers need to evaluate the cooling performance of their data centers during peak capacity operation to truly understand their cooling needs.
This type of detailed analysis is the key to optimizing data center cooling.This level of research requires people with the tools to determine where the hot spots are and how to correct them.
Different types of cooling require different services
Because precise cooling systems are designed in a way that makes them very different from the comfort air conditioning of a typical building, service providers without specific knowledge of how to maintain equipment may not be ready to handle the work.Inexperienced service providers greatly increase the risk of equipment delivery failures, and service providers trained with OEM factories help ensure accurate cooling systems operate at their best performance and efficiency points.
The continuous operation of precision cooling is necessary for the normal operation of data center IT equipment.This makes its maintenance extremely important.It also makes no sense to use services from service providers that may not have the expertise to maintain their performance levels, or to potentially undermine investment in precision air conditioning in enterprise data centers.
Some reasons for choosing high end custom website design
Website design, with the development of Internet +, a new round of consumption upgrade makes users' consumption habits and consumption psychology change rapidly. More enterprises pay attention to high-end customized website construction services. In the process of high-end customized service, the enterprise official network has become a major key point. The convenience of the Internet has no longer been explained too much. More and more users choose to understand and contact enterprises by querying information on the official website. Now let's talk about the reasons for designing high-end customized websites.
The design of high-end customized website is completed by senior planner, senior WEB programmer and senior page designer. It includes a series of services, such as early location analysis and planning, technology structure, website interface design and site architecture. Design and construction is generally customized website (customized).
There are a lot of free or cheap template websites on the Internet. Small building companies usually use a very low price to set up a template website, and you can make a website in 3-5 days. But the web site, the framework and the functional website that set up the template can not reflect the bright spot of the enterprise itself. The overall positioning and the website planning do not necessarily meet the expectations of the enterprise. And website code is the same, is not conducive to the late optimization of the website, template website keywords ranking is generally not good.
The high-end custom website design is a project. Professional website companies do pre research, then according to the characteristics of the enterprise industry and products or services, make unique website design for enterprises.
2, high-end custom website design brings high value to enterprises.
The higher price is not only reflected in the top-level domain name, the larger space, the stable server, but also reflected in the design planning cost. Although the high-end custom website design will be relatively expensive in the early stage, the high quality website will bring unpredictable value to the enterprise after its completion. So its production costs are higher than the ordinary web site.
3. Professional front-end page making
Website production based on the style of customer confirmation page production, and according to the key words provided by the plan, in the plate interface layout search engine optimization, the site to build experienced staff, see the web design map, can be very familiar with the JS, picture, code and other areas.
4, professional website background development project experience
The design and development of high-end custom website is based on the front-end interface, related functions and customer needs. The background is developed to facilitate the operation of the website manager, powerful function, simple operation, and can also add functions according to the needs of the enterprise, for example, member management system, login and registration system.
5, professional project test
Professional project testing includes website response speed, website code, web site chain, browser compatibility and so on. After the end of the work, the website is submitted to every search engine at the first moment to ensure that the website can be included in the first time, which is convenient for the promotion of the later period.
The design of high-end customized website is completed by senior planner, senior WEB programmer and senior page designer. It includes a series of services, such as early location analysis and planning, technology structure, website interface design and site architecture. Design and construction is generally customized website (customized).
There are a lot of free or cheap template websites on the Internet. Small building companies usually use a very low price to set up a template website, and you can make a website in 3-5 days. But the web site, the framework and the functional website that set up the template can not reflect the bright spot of the enterprise itself. The overall positioning and the website planning do not necessarily meet the expectations of the enterprise. And website code is the same, is not conducive to the late optimization of the website, template website keywords ranking is generally not good.
The high-end custom website design is a project. Professional website companies do pre research, then according to the characteristics of the enterprise industry and products or services, make unique website design for enterprises.
2, high-end custom website design brings high value to enterprises.
The higher price is not only reflected in the top-level domain name, the larger space, the stable server, but also reflected in the design planning cost. Although the high-end custom website design will be relatively expensive in the early stage, the high quality website will bring unpredictable value to the enterprise after its completion. So its production costs are higher than the ordinary web site.
3. Professional front-end page making
Website production based on the style of customer confirmation page production, and according to the key words provided by the plan, in the plate interface layout search engine optimization, the site to build experienced staff, see the web design map, can be very familiar with the JS, picture, code and other areas.
4, professional website background development project experience
The design and development of high-end custom website is based on the front-end interface, related functions and customer needs. The background is developed to facilitate the operation of the website manager, powerful function, simple operation, and can also add functions according to the needs of the enterprise, for example, member management system, login and registration system.
5, professional project test
Professional project testing includes website response speed, website code, web site chain, browser compatibility and so on. After the end of the work, the website is submitted to every search engine at the first moment to ensure that the website can be included in the first time, which is convenient for the promotion of the later period.
2018年7月18日 星期三
機房建置,維護方法詳解!
1、數據中心將建在哪裏
機房建置,分析新建的數據中心所在地的氣候條件是十分重要。這將有助於確定最合適的冷卻措施,其中包括水冷機組,機械製冷空調,自然空氣冷卻,間接空氣冷卻,絕熱冷卻等,這些都是爲了數據中心設施實現其更低的PUE目標。
2、需要多少個機架,它們的尺寸是多少
機架的數量決定數據中心的空間需求。傳統的它機架的尺寸爲600 x1000mm(寬x深),而一個空間爲100平方米的機房可以容納大約50個機架。當然機架也有其他的尺寸,而知道機架的尺寸和機架的數量,就很容易估測你的數據中心所需的空間。
3,需要什麼等級的數據中心
數據中心的層等級確定了數據中心的冗餘要求和電源分配路徑。對於一個Tier2級數據中心來說,部署“N + 1”架構的電源和冷卻設備的冗餘是足夠的。然而,對於一個Tier3級的數據中心設施,通常都會包括“N + 1”冷卻設備冗餘,具有雙供電2 N電源冗餘,以及獨立的雙路配電機架,因此,瞭解數據中心的等級可以決定需要的冗餘設計。
4,每個機架平均功率密度是多少
要注意的是,當設計數據中心的電源容量時,應該根據平均功率密度,而不是在最大額定電源,這是很重要的。機架的平均功率密度乘以機架的數量纔是數據中心的最大它負載量。然後,再加上數據中心的電源系統,冷卻系統和交換機和存儲設備等設施的功率。
爲了避免產生昂貴的成本,並充分利用電力系統,使數據中心具有大小合適的電源和空間,採用模塊化策略是明智的,可以降低成本,而不必犧牲未來擴展的靈活性。
5、運維人員應參加規劃設計工作
一。運維參與前期規劃設計,可彌補設計人員對系統運行管理知識的不足,提高設計質量,避免或消除設計缺欠;
b。運維參與前期規劃設計,可將運維階段的需求在規劃設計中得到充分考慮;
c。運維參與前期規劃設計,可充分了解和掌握所維護系統的結構,可靠性薄弱環節,遺留問題,潛在風險,有助於提高運維質量,有根據地制定運維計劃和切實可行的改造計劃。
6,避免受內外部因素影響,不能正確對待傾向,喜好,限制,約束的區別,不遵守科學設計原則
一。應避免受審批,決策等環節個別決策者影響,對一些關鍵功能按照個別人的意見進行刪減調整,導致最終交付的數據中心功能不能滿足運營和維護需求;
b。應避免出於傾向,喜好或利益驅動。在規劃設計階段部分設備廠商可能會通過誇大設備性能,混淆概念等手段影響規劃設計人員的方案制定和設備選型。
7日,交流機架或直流機架需要什麼級別的備份電池
服務器機架可能需要部署百分之百的直流電源,或百分之百的交流電源,或者是二者的組合。
例如,如果正在爲託管目的建設數據中心,可能有配備交流(UPS)供電系統的需求,而如果是要成爲一個電信設施,這可能需要部署直流電源系統。知道這些,就會知道所需要的直流電源或UPS電源系統的大小和規模。
在部署備份電池時,最好根據15分鐘備用放電時間進行配置。這樣部署備用電池,不會顯著增加資本支出,雖然這將很難自圓其說,但這更符合成本效益。企業需要提高備用發電機組的冗餘度,而不是在增加電池數量浪費更多的資金。
8日,避免輕規劃設計,重施工建設
業內存在輕規劃設計,重施工建設的現狀,主要表現在:
一。先建樓體結構,後規劃數據中心,爲數據中心規劃設計帶來難以克服的困難;
b。機房建設和設備安裝完畢即開始改造的現象普遍存在;
c。先確定設備,再確定方案,由於所購設備功能不滿足方案要求,或場地不滿足安裝條件要求,因而設備尚未運行就要更換;
d。建設結構很難滿足數據中心場地佈局要求,使機房分區規劃不合理,空調室外機無法安裝或距離太遠;動力室與主機房距離太遠,增加傳輸和管理困難,增加成本,降低可靠性。
9日,避免忽視對系統可維護性和可修復性設計
系統三分建設,七分維護,任何設備都可能發生故障,可快速修復已經成爲提高可用性的關鍵指標。
忽視可維護性和可修復性的現象表現在:
一。規劃設計階段未考慮後期維護通道,維護空間,例如設備距離牆壁太近,電池靠牆擺放,線纜佈局不合理,線纜管路或走線架擋住上方弱電線槽導致後期無法維修,維護工具難以施展等;
b。故障發生時,應急物資和備件無法快速搬運,故障設備和器件更換無維修操作空間等問題,延誤了故障處置時限甚至引發重大事故;
c。未考慮後期發生故障進行設備維護時系統的冗餘保障能力;
d。未盡可能採用自動化手段,最大程度減少維護人員手動操作環節,降低因手動操作存在的不確定性和不可控性。
10日,避免可用性設計缺乏科學依據
系統可用性是數據中心規劃設計的最重要的指標,但規劃設計時缺乏科學依據,主要表現是:
一。數據中心在規劃設計時都會進行各系統可靠性的推算,但目前各設計院,不同的設計人員對可靠性的推算依據和數據來源尚未統一,造成對同一數據中心的設計等級和可靠性存在不同定義和不同的結果;
b。對可用性存在着先進行規劃設計,施工,建設完成後再反推設計等級的案例,並以反推的等級標準向數據中心用戶進行推介。此爲本末倒置的設計,往往因爲設計中的某些關鍵缺陷導致雖然絕大部分設計滿足等級要求,但因爲關鍵缺陷的存在造成等級下降;
c。只注意設備或環節(子系統)的可用性,而忽略在整個系統中各子系統之間的相關性對可用性的影響。
11日,避免在脫離實際需要和可行性情況下,確定高指標
在規劃設計初期,主觀臆斷確定數據中心的功能指標,不切實際地一味追求規模大,高可用性等級,高機架功率密度,低能耗指標PUE。
而具體規劃設計時,又沒有嚴格按照規劃原則和程序做詳細的論證,具體方案和實際措施與總體規劃部匹配,其結果是:
一。由於實際需求不明確,缺乏可行性的必要條件,反覆設計,修改,不僅造成成本的浪費,還大大延長了建設週期;
b。已建成並投入使用的機房得不到充分利用,究其原因或因無預想的業務需求量,或因機房條件不滿足用戶需求而必須進行再優化改造才能使用;
c。規劃設想的功能不能實現,如系統可用性達不到規劃等級,製冷方案不支持規劃的機架高功率密度,發電機不支持系統連續運行條件,過度規劃使系統能耗指標PUE居高不下等。
12日,避免重設備輕系統的認識誤區
業內特別是規劃設計人員普遍存在着重設備輕系統和重局部忽視大局的現象,主要表現在:
一。先確定設備規格型號甚至生產廠家,然後根據設備選擇或修改設計方案;
b。供電系統按最高可用等級2 n冗餘設計,但所設計的結果是僅僅UPS系統有2 n功能,而整個供電系統卻存在單路徑故障點;
c。整個系統按最高等級冗餘容錯系統設計,但是空調製冷設備卻是單路徑供電;
d。爲系統配置了交流備用能源柴油發電機,但發電機沒有自動啓動功能,因爲規劃設計者缺乏連續製冷也是系統連續運行的重要條件的認識。
13日注重統籌設計
提高系統統籌設計能力對優質地完成規劃設計任務是非常重要的。
一。在數據中心建設過程中存在着大量因規劃設計對分階段,分專業實施階段工程,以及不同專業施工間銜接問題考慮不足造成交付的數據中心不滿足業務及維護需求,有些問題甚至需要大筆投資進行改造方可完成;
b。不同設計人員只關注自身所負責內容,對於其他專業的是否完美銜接,是否與其他專業設計之間存在矛盾和衝突缺乏全局考慮;
c。規劃設計人員對未來業務發展缺乏準確把握,對後期容量管理,擴容等方面考慮不足;
d。規劃設計人員對周圍資源環境和物理環境不熟悉,所設計的方案會出現實施可行性差或者爲後來運維工作帶來難以克服的困難。
機房建置,分析新建的數據中心所在地的氣候條件是十分重要。這將有助於確定最合適的冷卻措施,其中包括水冷機組,機械製冷空調,自然空氣冷卻,間接空氣冷卻,絕熱冷卻等,這些都是爲了數據中心設施實現其更低的PUE目標。
2、需要多少個機架,它們的尺寸是多少
機架的數量決定數據中心的空間需求。傳統的它機架的尺寸爲600 x1000mm(寬x深),而一個空間爲100平方米的機房可以容納大約50個機架。當然機架也有其他的尺寸,而知道機架的尺寸和機架的數量,就很容易估測你的數據中心所需的空間。
3,需要什麼等級的數據中心
數據中心的層等級確定了數據中心的冗餘要求和電源分配路徑。對於一個Tier2級數據中心來說,部署“N + 1”架構的電源和冷卻設備的冗餘是足夠的。然而,對於一個Tier3級的數據中心設施,通常都會包括“N + 1”冷卻設備冗餘,具有雙供電2 N電源冗餘,以及獨立的雙路配電機架,因此,瞭解數據中心的等級可以決定需要的冗餘設計。
4,每個機架平均功率密度是多少
要注意的是,當設計數據中心的電源容量時,應該根據平均功率密度,而不是在最大額定電源,這是很重要的。機架的平均功率密度乘以機架的數量纔是數據中心的最大它負載量。然後,再加上數據中心的電源系統,冷卻系統和交換機和存儲設備等設施的功率。
爲了避免產生昂貴的成本,並充分利用電力系統,使數據中心具有大小合適的電源和空間,採用模塊化策略是明智的,可以降低成本,而不必犧牲未來擴展的靈活性。
5、運維人員應參加規劃設計工作
一。運維參與前期規劃設計,可彌補設計人員對系統運行管理知識的不足,提高設計質量,避免或消除設計缺欠;
b。運維參與前期規劃設計,可將運維階段的需求在規劃設計中得到充分考慮;
c。運維參與前期規劃設計,可充分了解和掌握所維護系統的結構,可靠性薄弱環節,遺留問題,潛在風險,有助於提高運維質量,有根據地制定運維計劃和切實可行的改造計劃。
6,避免受內外部因素影響,不能正確對待傾向,喜好,限制,約束的區別,不遵守科學設計原則
一。應避免受審批,決策等環節個別決策者影響,對一些關鍵功能按照個別人的意見進行刪減調整,導致最終交付的數據中心功能不能滿足運營和維護需求;
b。應避免出於傾向,喜好或利益驅動。在規劃設計階段部分設備廠商可能會通過誇大設備性能,混淆概念等手段影響規劃設計人員的方案制定和設備選型。
7日,交流機架或直流機架需要什麼級別的備份電池
服務器機架可能需要部署百分之百的直流電源,或百分之百的交流電源,或者是二者的組合。
例如,如果正在爲託管目的建設數據中心,可能有配備交流(UPS)供電系統的需求,而如果是要成爲一個電信設施,這可能需要部署直流電源系統。知道這些,就會知道所需要的直流電源或UPS電源系統的大小和規模。
在部署備份電池時,最好根據15分鐘備用放電時間進行配置。這樣部署備用電池,不會顯著增加資本支出,雖然這將很難自圓其說,但這更符合成本效益。企業需要提高備用發電機組的冗餘度,而不是在增加電池數量浪費更多的資金。
8日,避免輕規劃設計,重施工建設
業內存在輕規劃設計,重施工建設的現狀,主要表現在:
一。先建樓體結構,後規劃數據中心,爲數據中心規劃設計帶來難以克服的困難;
b。機房建設和設備安裝完畢即開始改造的現象普遍存在;
c。先確定設備,再確定方案,由於所購設備功能不滿足方案要求,或場地不滿足安裝條件要求,因而設備尚未運行就要更換;
d。建設結構很難滿足數據中心場地佈局要求,使機房分區規劃不合理,空調室外機無法安裝或距離太遠;動力室與主機房距離太遠,增加傳輸和管理困難,增加成本,降低可靠性。
9日,避免忽視對系統可維護性和可修復性設計
系統三分建設,七分維護,任何設備都可能發生故障,可快速修復已經成爲提高可用性的關鍵指標。
忽視可維護性和可修復性的現象表現在:
一。規劃設計階段未考慮後期維護通道,維護空間,例如設備距離牆壁太近,電池靠牆擺放,線纜佈局不合理,線纜管路或走線架擋住上方弱電線槽導致後期無法維修,維護工具難以施展等;
b。故障發生時,應急物資和備件無法快速搬運,故障設備和器件更換無維修操作空間等問題,延誤了故障處置時限甚至引發重大事故;
c。未考慮後期發生故障進行設備維護時系統的冗餘保障能力;
d。未盡可能採用自動化手段,最大程度減少維護人員手動操作環節,降低因手動操作存在的不確定性和不可控性。
10日,避免可用性設計缺乏科學依據
系統可用性是數據中心規劃設計的最重要的指標,但規劃設計時缺乏科學依據,主要表現是:
一。數據中心在規劃設計時都會進行各系統可靠性的推算,但目前各設計院,不同的設計人員對可靠性的推算依據和數據來源尚未統一,造成對同一數據中心的設計等級和可靠性存在不同定義和不同的結果;
b。對可用性存在着先進行規劃設計,施工,建設完成後再反推設計等級的案例,並以反推的等級標準向數據中心用戶進行推介。此爲本末倒置的設計,往往因爲設計中的某些關鍵缺陷導致雖然絕大部分設計滿足等級要求,但因爲關鍵缺陷的存在造成等級下降;
c。只注意設備或環節(子系統)的可用性,而忽略在整個系統中各子系統之間的相關性對可用性的影響。
11日,避免在脫離實際需要和可行性情況下,確定高指標
在規劃設計初期,主觀臆斷確定數據中心的功能指標,不切實際地一味追求規模大,高可用性等級,高機架功率密度,低能耗指標PUE。
而具體規劃設計時,又沒有嚴格按照規劃原則和程序做詳細的論證,具體方案和實際措施與總體規劃部匹配,其結果是:
一。由於實際需求不明確,缺乏可行性的必要條件,反覆設計,修改,不僅造成成本的浪費,還大大延長了建設週期;
b。已建成並投入使用的機房得不到充分利用,究其原因或因無預想的業務需求量,或因機房條件不滿足用戶需求而必須進行再優化改造才能使用;
c。規劃設想的功能不能實現,如系統可用性達不到規劃等級,製冷方案不支持規劃的機架高功率密度,發電機不支持系統連續運行條件,過度規劃使系統能耗指標PUE居高不下等。
12日,避免重設備輕系統的認識誤區
業內特別是規劃設計人員普遍存在着重設備輕系統和重局部忽視大局的現象,主要表現在:
一。先確定設備規格型號甚至生產廠家,然後根據設備選擇或修改設計方案;
b。供電系統按最高可用等級2 n冗餘設計,但所設計的結果是僅僅UPS系統有2 n功能,而整個供電系統卻存在單路徑故障點;
c。整個系統按最高等級冗餘容錯系統設計,但是空調製冷設備卻是單路徑供電;
d。爲系統配置了交流備用能源柴油發電機,但發電機沒有自動啓動功能,因爲規劃設計者缺乏連續製冷也是系統連續運行的重要條件的認識。
13日注重統籌設計
提高系統統籌設計能力對優質地完成規劃設計任務是非常重要的。
一。在數據中心建設過程中存在着大量因規劃設計對分階段,分專業實施階段工程,以及不同專業施工間銜接問題考慮不足造成交付的數據中心不滿足業務及維護需求,有些問題甚至需要大筆投資進行改造方可完成;
b。不同設計人員只關注自身所負責內容,對於其他專業的是否完美銜接,是否與其他專業設計之間存在矛盾和衝突缺乏全局考慮;
c。規劃設計人員對未來業務發展缺乏準確把握,對後期容量管理,擴容等方面考慮不足;
d。規劃設計人員對周圍資源環境和物理環境不熟悉,所設計的方案會出現實施可行性差或者爲後來運維工作帶來難以克服的困難。
Datacenter migration, how to choose partners?
Datacenter migration, research institutions MarketsandMarkets survey report predicts that 2022 unified communications (UC) and general collaboration market scale will reach $6.2 billion, so the companies are working to develop to help customers implement these productivity and increase their income.But even if there is interest in the capabilities of such devices, the question remains: how do you choose a data center partner that hosts the platform?
If a data center partner is chosen incorrectly, it may lead to poor connectivity, limited infrastructure, or limited business growth opportunities in the future, leading to a loss of competitiveness.Therefore, when selecting a multi-service data center partner, the following points need to be considered:
1. Corporate reputation
Some initial issues need to be considered when selecting a data center provider.First, the provider should have a good reputation in the industry and a good track record in successfully deploying solutions.Every company is unique in its method, therefore, a comprehensive understanding of its function (including the SIP protocol and connection of the infrastructure level, and they provide data center layer) is also very important, so companies need to understand the reliability of the architecture.
There is no harm in communicating with the existing customer base of data center providers, which will help to confirm their industry reputation and service capabilities and enhance their overall understanding of data center providers.
2. End-to-end stack ownership
Companies should look for a data center provider that invests in building and operating their own infrastructure, data centers, and connectivity.In general, enterprises invest in solutions involving multiple providers, which only adds complexity and costs.
Vendors that can provide a complete stack of communications and terminals will provide greater efficiency.This is because they can have more control over all aspects of quality and delivery so that the provider can provide a higher level of service agreement from which the enterprise can benefit.
3. Technical strength
Enterprises should also and has some of the key technical features of the data center provider cooperation, to provide comprehensive security cover function, for example, allowing them to create network abstraction layer, the layer can run multiple independent solution, enhance the security of the physical network.
In addition, the enterprises to select the data center provider should have the management level and support the operator of the SIP, connectivity and session border control (SBC) cluster, they provide the highest level of bandwidth, call quality, scalability, and minimize the interruption to network and service.They should also have used in a wide area network (WAN) connects the powerful multi-protocol label switching (MPLS) infrastructure, this will ensure that the selection of data center providers can use the latest technology, and process connections across a variety of communication media.
4. Flexibility of change
As consolidation becomes more prevalent, companies' partners do not want them to be acquired or shut down entirely.Therefore, enterprises need to pay attention to those who provide data center and a full range of products provider, these products in all cases with elasticity, and can be used in a mixed solution, high level disaster recovery strategy, as well as the flexible layered service when necessary.
Moreover, in a rapidly growing market, it is important for companies to assess whether providers are at risk of being acquired or merged.The provider should have financial security, which can not only reduce the possibility of financial risks, but also ensure continuous investment in product and peripheral infrastructure research and development.
In short, the enterprise needs and is able to process development, implementation, training and managed all affairs of partners, to the business in the future of protection, and did not bring the complexity of using multiple providers of services.At the same time, it provides enterprises with better transactions, higher efficiency, service delivery and support, migration, and renewal.
If a data center partner is chosen incorrectly, it may lead to poor connectivity, limited infrastructure, or limited business growth opportunities in the future, leading to a loss of competitiveness.Therefore, when selecting a multi-service data center partner, the following points need to be considered:
1. Corporate reputation
Some initial issues need to be considered when selecting a data center provider.First, the provider should have a good reputation in the industry and a good track record in successfully deploying solutions.Every company is unique in its method, therefore, a comprehensive understanding of its function (including the SIP protocol and connection of the infrastructure level, and they provide data center layer) is also very important, so companies need to understand the reliability of the architecture.
There is no harm in communicating with the existing customer base of data center providers, which will help to confirm their industry reputation and service capabilities and enhance their overall understanding of data center providers.
2. End-to-end stack ownership
Companies should look for a data center provider that invests in building and operating their own infrastructure, data centers, and connectivity.In general, enterprises invest in solutions involving multiple providers, which only adds complexity and costs.
Vendors that can provide a complete stack of communications and terminals will provide greater efficiency.This is because they can have more control over all aspects of quality and delivery so that the provider can provide a higher level of service agreement from which the enterprise can benefit.
3. Technical strength
Enterprises should also and has some of the key technical features of the data center provider cooperation, to provide comprehensive security cover function, for example, allowing them to create network abstraction layer, the layer can run multiple independent solution, enhance the security of the physical network.
In addition, the enterprises to select the data center provider should have the management level and support the operator of the SIP, connectivity and session border control (SBC) cluster, they provide the highest level of bandwidth, call quality, scalability, and minimize the interruption to network and service.They should also have used in a wide area network (WAN) connects the powerful multi-protocol label switching (MPLS) infrastructure, this will ensure that the selection of data center providers can use the latest technology, and process connections across a variety of communication media.
4. Flexibility of change
As consolidation becomes more prevalent, companies' partners do not want them to be acquired or shut down entirely.Therefore, enterprises need to pay attention to those who provide data center and a full range of products provider, these products in all cases with elasticity, and can be used in a mixed solution, high level disaster recovery strategy, as well as the flexible layered service when necessary.
Moreover, in a rapidly growing market, it is important for companies to assess whether providers are at risk of being acquired or merged.The provider should have financial security, which can not only reduce the possibility of financial risks, but also ensure continuous investment in product and peripheral infrastructure research and development.
In short, the enterprise needs and is able to process development, implementation, training and managed all affairs of partners, to the business in the future of protection, and did not bring the complexity of using multiple providers of services.At the same time, it provides enterprises with better transactions, higher efficiency, service delivery and support, migration, and renewal.